ACH High Voltage Motor Controllers
Whether your vehicles go on the road or off-road, the rugged design of the ACH ensures a reliable performance without the need for maintenance. All ACH models are available with CAN bus communication.
To ensure sustainable functional safety and electrical safety both on-road and off-road, we work according to the latest standards used in the industry.
Security and safety are key! We use best-practice cybersecurity management according to established standards, we stay up to date and vigilant!
Powerful flexibility
The ACH comes in two sizes: Medium and Large and both versions are available in the 350 V - 650 V or 450 V - 850V range.
ACH35M30 and ACH65M30
ACH M
Inmotion's ACH M is a family of inverters/motor controllers with power levels from 100 to 250 kVA, designed for nominal voltages between 350 V and 700 V. The ACH is developed with traction, hydraulic pump and generator applications in mind, which makes it an ideal choice for hybrid or battery-powered electric vehicles and machines.
ACH35L70 and ACH65L50
ACH L
.The ACH L is based on the ACH M and is scaled up to power levels from 150 to 400 kVA, designed for nominal voltages between 350 V and 700 V. The ACH L is developed with traction and generator applications in mind, which makes it an ideal choice for hybrid or battery-powered electric vehicles and machines where high power levels are required.
- Features
- Specifications
- Models
Features
- Rugged IP6K9K design suitable for the demanding environment of electric vehicles
- 4-quadrant, synchronous or asynchronous AC motor control, with speed, torque and DC-voltage control modes
- Field proven control SW platform used for on-highway and off- highway vehicles
- Software quality is assured through development and review processes designed for compliance with Automotive SPICE©
- CAN communication, J1939 and/or CANopen with support for diagnostics and software download
- With continuous power levels up to 300 kVA, the ACH is ideally suited for hybrid as well as fully electric vehicle applications
- Nominal voltage 350 and 650 V. Fully operational from 100 to 750 V bus voltage
- Liquid (WEG) cooled
- Automatic protection against overheating and over-voltage
- Redundant Discharge of DC-capacitors
- Internal EMI filtering of the dc-bus eliminates interference with other electronic equipment and allows parallel operation of several ACH controllers
- Powerful standard firmware features as well as extensive software configurability ensures optimal system functionality
- Designed for working life in excess of 60 000 hours
- Extensive and powerful event handling and data logging simplifies troubleshooting and minimizes vehicle down time
- Interlock for personal safety
- Optional adapter kit for pre-assembly of shielded high voltage cables
Specifications
GENERAL |
|
Compatible motor types |
Induction machines, PMAC, Sync. reluctance |
Motor feedback types |
Resolver or incremental encoder/analog (sin-cos) |
Control mode |
Torque, speed or dc voltage control |
Communication |
CAN (J1939, CANopen) |
CONNECTIONS |
|
Logic connector |
TE Leavyseal |
Power connectors | M8 cable lugs |
TEMPERATURE AND COOLING | |
Nominal WEG coolant temp/flow |
60 °C @ 20l/min |
Ambient operating temperature |
-40 °C to 85 °C |
ELECTRICAL SAFETY AND EMC |
|
High voltage safety |
According to ECE R100 |
EMC |
According to ECE R10 |
RATINGS |
|
ACH35 |
Nominal DC voltage 350 V |
ACH65 |
Nominal DC voltage 650 V |
Models
Model |
Nominal Voltage DC |
Peak current* |
Cont. current** |
Peak power*** |
Cont. power*** |
ACH35M30 |
350 V |
320 |
225 |
137 kVA |
96 kVA |
ACH35L70 |
700 |
400 |
299 kVA |
172 kVA |
|
ACH65M30 |
350 V |
320 |
225 |
137 kVA |
96 kVA |
650 V |
255 kVA |
179 kVA |
|||
ACH65L50 |
350 V |
500 |
375 |
214 kVA |
161 kVA |
650 V |
398 kVA |
299 kVA |
* 60 sec rating
** At coolant temp 60 °C (140 °F), Ambient temp 85 °C (185 °F), and Switching frequency 4 kHz